Categories

GSI 39 Auto Tympanometer

Quick Overview

GSI 39 Auto Tympanometer is lightweight and portable detection and documentation of middle ear pathologies fast and accurate provides a flexible, screening product for tympanometry, acoustic reflex measurements and audiometry to meet your testing needs today and in the future 

More details

$4,115.00

On sale On sale!

GSI 39 Auto Tympanometer is lightweight and portable detection and documentation of middle ear pathologies fast and accurate provides a flexible, screening product for tympanometry, acoustic reflex measurements and audiometry to meet your testing needs today and in the future

 
Calibration Complies with:
 
ANSI S3.6-2010 Audiometer Specifications
ANSI S3.39-1987 ( R 2012 ) Immittance Specifications
OSHA 1983 Exhaustive Calibration Specifications 
Manufacture Specifications
 

GSI 39 Auto Tympanometer  Comes With

1.) Gsi 39 Auto Tymp (Calibrated w/ CERTIFICATE)
2.) Power Supply w/ Cord
3.) Calibration Test Chamber
4.) Grason Stradler Tymp Tips
5.) User Manual 
6.) Quick Reference Guide Sheet
7.) Telephonic Headphones (Calibrated W/ CERTIFICATE) 
8.) NEW CALIBRATION CERTIFICATE


A high frequency, 1kHz probe tone, can be added for those users needing this feature.

* Lightweight and portable
* Space-saving ergonomic design
* Accurate, reliable test results
* Customized display and printed hard copy of test results
* Five versions to meet individual requirements and budgets


 

TECHNICAL SPECIFICATIONS :

 

PROBE TONE: Frequency: 226 Hz +⁄- 2%
Intensity: 85.5 dB SPL +⁄- 2.0 dB; measured with an IEC 60318-5 2 cc coupler
Harmonic Distortion: < 3%
COMPLIANCE: Range: 0.0 to 1.5 cm3 and 0.0 to 3.0 cm3
Note: Range is automatically selected based on amplitude of the tymp peak.
Accuracy: +⁄- 5% or +⁄- 0.1 cm3, whichever is greater
PRESSURE: Range: +200 to -400 daPa
Setting The Clinical Standard
Accuracy: +⁄- 10 daPa or 15%, whichever is greater, measued in 0.5 to 2.0 cc cavities
Sweep Rate: 600 daPa/sec, except near tympanogrm peak where sweep rate slows to 200 daPa/sec to provide better definition of the peak compliance
Sweep Direction: Positive to negative
Gradient: Tymp pressure width at 50% of peak compliance
Test time: Approximately 1 second
REFLEX: Frequencies: 500, 1000, 2000, and 4000 Hz
Accuracy: +⁄- 3%
Total Harmonic Distortion: Rise/ Fall Times: 5 to 10 msec
OUTPUT LEVELS (MEASURED WITH A 2CC COUPLER): IPSI
- 500 and 4000 Hz: 80, 90, 100 dB HL, +⁄- 3 dB
- 1000 and 2000 Hz: 85, 95, 105 dB HL, +⁄- 3 dB
CONTRA
- 500, 1000, 2000, 4000 Hz: 90, 100, 110 dB HL, +⁄- 3 dB
Note 1: Stimuli are time multiplexed with the probe tone (93 ms ON, 66 ms OFF);
Note 2: Contra available on versions 2 and 3 only.
Pressure: Automatically set to pressure at peak compliance with an offset of + or – 20 daPa depending on location of peak compliance
Determination of reflex present: Compliance change of 0.05 cm3 or greater
Test time: 2 to 12 second

 

GSI 39 Auto Tympanometer Datasheet

  • Product Name:GSI 39 Auto Tympanometer
  • Price: $ 4,115.00
  • Product Width: 0.00 in
  • Product Height: 0.00 in
  • Product Depth: 0.00 in
  • Product Weight: 0.00 lb
  • Description: GSI 39 Auto Tympanometer is lightweight and portable detection and documentation of middle ear pathologies fast and accurate provides a flexible, screening product for tympanometry, acoustic reflex measurements and audiometry to meet your testing needs today and in the future 
Path: > > GSI 39 Auto Tympanometer

Write your review

GSI 39 Auto Tympanometer

GSI 39 Auto Tympanometer

GSI 39 Auto Tympanometer is lightweight and portable detection and documentation of middle ear pathologies fast and accurate provides a flexible, screening product for tympanometry, acoustic reflex measurements and audiometry to meet your testing needs today and in the future 